Glycerophospholipids are glycerol-based phospholipids. They are the main component of biological membranes. Glycerophospholipids present a significant challenge in high level of accuracy in lipid quantitation, given the headgroup diversity, large number of possible acyl chain combinations, and vast range of ionization efficiency of species. The glycerophospholipids include hundreds of analytes encountered in routine profiling and over a thousand species detectable from repeated fragmentation scanning from some samples.
Equipped with advanced electrospray ionization mass spectrometry (ESIMS) for Glycerophospholipids quantification, sophisticated detection techniques, and a panel of experienced scientists and technicians, Creative Proteomics provide customer-tailored service with rapid analysis procedures and easy to read report, to speed up your scientific research. For glycerophospholipids, we offer several approaches depending on the depth of analysis that is required.
1. Phospholipid Class Panel
The class panel consists of a quantitative phospholipid class scan. We can quantify all of these classes or limit to only the ones that you select.
2. Comprehensive Phospholipid Panel
The comprehensive panel analyzes all individual isobaric species contained within each class.
Technology Platform:
ESI Liquid Chromatography Mass Spectrometry (ESI- LC/MS)
Sample Type:
Cells
Animals
Humans
Minimum sample quantity
Cells: 500,000
Fluids: 50 microL
Tissues: 5 mg
Glycerophospholipids could monitored in This Service | ||
---|---|---|
lysoPC a C6:0 | PC aa C36:3 | PC ae C36:0 |
lysoPC a C14:0 | PC aa C36:4 | PC ae C36:1 |
lysoPC a C16:0 | PC aa C36:5 | PC ae C36:2 |
lysoPC a C16:1 | PC aa C36:6 | PC ae C36:3 |
lysoPC a C17:0 | PC aa C38:0 | PC ae C36:4 |
lysoPC a C18:0 | PC aa C38:1 | PC ae C36:5 |
lysoPC a C18:1 | PC aa C38:3 | PC ae C38:0 |
lysoPC a C18:2 | PC aa C38:4 | PC ae C38:1 |
lysoPC a C20:3 | PC aa C38:5 | PC ae C38:2 |
lysoPC a C20:4 | PC aa C38:6 | PC ae C38:3 |
lysoPC a C24:0 | PC aa C40:1 | PC ae C38:4 |
lysoPC a C26:0 | PC aa C40:2 | PC ae C38:5 |
lysoPC a C26:1 | PC aa C40:3 | PC ae C38:6 |
lysoPC a C28:0 | PC aa C40:4 | PC ae C40:0 |
lysoPC a C28:1 | PC aa C40:5 | PC ae C40:1 |
PC aa C24:0 | PC aa C40:6 | PC ae C40:2 |
PC aa C26:0 | PC aa C42:0 | PC ae C40:3 |
PC aa C28:1 | PC aa C42:1 | PC ae C40:4 |
PC aa C30:0 | PC aa C42:2 | PC ae C40:5 |
PC aa C30:2 | PC aa C42:4 | PC ae C40:6 |
PC aa C32:0 | PC aa C42:5 | PC ae C42:0 |
PC aa C32:1 | PC aa C42:6 | PC ae C42:1 |
PC aa C32:2 | PC ae C30:0 | PC ae C42:2 |
PC aa C32:3 | PC ae C30:1 | PC ae C42:3 |
PC aa C34:1 | PC ae C30:2 | PC ae C42:4 |
PC aa C34:2 | PC ae C32:1 | PC ae C42:5 |
PC aa C34:3 | PC ae C32:2 | PC ae C44:3 |
PC aa C34:4 | PC ae C34:0 | PC ae C44:4 |
PC aa C36:0 | PC ae C34:1 | PC ae C44:5 |
PC aa C36:1 | PC ae C34:2 | PC ae C44:6 |
PC aa C36:2 | PC ae C34:3 |
Ordering Procedure:
With integrated set of separation, characterization, identification and quantification systems featured with excellent robustness & reproducibility, high and ultra-sensitivity, Creative Proteomics provides reliable, rapid and cost-effective Lipidomics services.